4. Get Started
4.1. Items in the Box
AMRrobot body
The manual charger has independent packaging.
4.2. Instructions for Use
This chapter introduces how to unbox AMR.
Note
Note: Please keep the original packaging for future transportation of the robot.
Manually rotate to loosen the butterfly buckle to remove the cover plate.
Remove the cover plate (ramp), take out the ramp auxiliary plate.
Remove the side panel, take out the protective foam board, and set up the ramp.
Push the robot down the ramp onto the ground. Be careful during this process to avoid bumps.
Figure 4.2-1 AMR Packaging
Figure 4.2-2 Remove the Cover Plate
4.3. Power On and Off
4.3.1. Power On the Device
The left image shows the power-off state, and turning clockwise switches to the right image which is the powered-on state, with the device being powered on.
Figure 4.3-1 Robot Power-On
4.4. Connect AMR
Connect the AMR and laptop with an Ethernet cable, change the computer IP to 192.168.58.3. Open the browser and enter http://192.168.58.3:3000.
Figure 4.4-1 Login Interface
4.5. Manual Joystick Control
This section allows users to directly interact with the AMR through a software interface, including manual control and environmental mapping.
Function Entry: Located in the “Manual Control” panel or navigation bar of the software main interface.
Figure 4.5-1 Joystick Control Interface
The usage steps for the virtual joystick component on the interface are as follows:
Ensure the robot is in manual mode and confirm that there is sufficient safety space around it.
Locate and focus on the virtual joystick component on the interface.
Move the mouse cursor to the center point of the joystick.
Hold down the left mouse button and drag the joystick center point in the expected direction of movement:
Drag forward or backward: Control the robot to move straight ahead or back; the greater the dragging amplitude, the faster the robot’s movement speed.
Drag left or right: Control the robot to perform an arc movement or rotate in place to the left or right.
Drag diagonally: Synthesize linear and angular velocities to move the robot along the corresponding curved path.
When it is necessary to stop the robot, release the left mouse button, the joystick will automatically return to center, and the robot will immediately cease movement.
4.6. Automatic Mode
Figure 4.6-1 Enter Task Options
Create Task
Function Description: By editing the AMR, create the tasks it will perform. The operational steps are as follows:
Step1: Enter the task name to create the task.
Figure 4.6-2 Create Task
Step2: Click Edit Task, you can edit three major items: movement, logic, and signals.
Figure 4.6-3 Editing Task
Step3: You can edit the movement - point position.
Figure 4.6-4 Add Points
Figure 4.6-5 Point Addition Completed
Step4: You can edit the movement-rotation.
Figure 4.6-6 Add Rotation
Figure 4.6-7 Add Rotation Completed
Step5: Logic-variables can be edited.
Figure 4.6-8 Add Variable
Figure 4.6-9 Adding Variable Completed
Step6: Logic can be edited - wait.
Figure 4.6-10 Add Wait
Figure 4.6-11 Add Wait for Completion
Step7: Logic can be edited - loop, interrupt, continue.
Figure 4.6-12 Add Always Loop
Figure 4.6-13 Add Always Loop Completion
Figure 4.6-14 Add Limited Number of Cycles
Figure 4.6-15 Add a Limited Number of Loop Cycles Completed
Figure 4.6-16 Add a Separate Conditional Loop
Figure 4.6-17 Adding Multiple Conditional Loops
Figure 4.6-18 Add Conditional Loop Completed
Step8: Logic-judgment can be edited.
Figure 4.6-19 Add Judgment
Figure 4.6-20 Add Judgment Completion
Step9: You can edit the signal - set the output.
Figure 4.6-21 Add Settings Output
Figure 4.6-22 Add Setting Output Completed
Step10: You can edit the signal - obtain output.
Figure 4.6-23 Add Output Acquisition
Figure 4.6-24 Add Obtain Output Completion
Step11: The signal can be edited - obtain input.
Figure 4.6-25 Add Input Acquisition
Figure 4.6-26 Add Input Acquisition Completion
Step12: Finally save the task
Execute Task
Function Description: Execute an edited and saved task script, enabling the robot to automatically complete a series of tasks defined in the script. Operation Process:
Step1: In the “Script Management” interface, add the Lua script to the task queue.
Step2: Click the “Run Script” button. Users can view the robot’s task status in real time on the interface.
Step3: To achieve operation stop, you can click the Stop Script button to interrupt the task.
Figure 4.6-27 Running Tasks
4.7. Robot Charging
Note
Name: Charging Precautions
Explanation: When charging in the designated area for AMR battery swapping and charging, it should be away from open flames, high temperatures, humidity, and densely populated work areas. Vehicle or battery disassembly, welding, and other maintenance activities must not be set up within this area.
AMR factory battery can be used for 4-5 hours, after which it needs to be charged. Please use the original charger. The specific charging steps are as follows:
Ensure the robot currently has no tasks and is in a stopped state.
Turn off the switch on the right side of the AMR, and the entire machine will immediately power down, completing the shutdown process.
Note
If the robot is shut down due to transportation, maintenance, or repair, the battery switch must be turned off.
4.7.1. Manual Charging
Figure 4.7-1 Switch Status of the Battery Drawer
Figure 4.7-2 Charging Connector
When in the on state, pull out the battery drawer, remove the charging connector within the red box, and connect a dedicated charger for charging. The charging process will take approximately 2 hours.
4.7.2. Automatic Charging
Low Battery Warning
Figure 4.7-3 Low Power Warning Popup
Step1: When the power is low, a warning prompt pops up on the page, and the user must click “I know” to proceed with other operations.
Figure 4.7-4 Low Power Warning
Step2: After the pop-up window closes, if the user has not performed a charging operation, the navigation bar warning will remain highlighted. Clicking on the icon will display a low battery warning prompt.
Charging Station Location and Attributes
The location icons of charging stations will be displayed on the map, and clicking with the mouse will show the current charging pile attribute information.
Figure 4.7-5 Charging Station Location and Attributes
Automatic Charging and Charging Threshold Setting
General panel selects the low power auto-charging switch. After enabling, the device will automatically go to the charging station for charging when it reaches the minimum power threshold; The threshold setting supports two methods: you can drag the slider to select the threshold range (the lowest power is 10%), or manually enter the threshold number.
Figure 4.7-6 Charging Threshold Settings
Charging Operation (Manual, Automatic Operation)
Table 4.7-7 State of Charge
Step1: When manually charging, click the power icon in the navigation bar, the power status bar will appear, then click the start charging button.
Figure 4.7-8 Proceed to the Charging Station
Step2: After manually clicking the charging button, the device will automatically go to the charging station for charging. During this process, no other operations can be performed, and the interface will continuously loop the animation of going to the charging pile until charging starts. When the automatic charging function is enabled, after the alarm pop-up window is closed, the device will automatically go to the charging pile for charging, and the interface will continuously loop the animation of going to the charging pile.
Figure 4.7-9 is Charging
Step3: After charging starts, a pop-up window displays the current charging status, and you can choose to manually end the charging.
Figure 4.7-10 End of Charging
Step4: When charging is complete, the relevant processes need to wait for a period of time to close, and the interface will display an execution waiting animation.
4.8. Map/Navigation Mode Switching
In the “Installation - Map” interface, click the “Edit” button to enter the map details interface for switching between mapping and navigation modes.
Note
Name: Map Building / Navigation Mode Button
Explanation: When the map is applied, the button being grayed out represents the navigation mode; clicking the button will switch to the mapping mode, and after a successful switch, the button being highlighted in orange represents the mapping mode.
Figure 4.8-1 Mapping/Navigation Mode Switching Entry
Figure 4.8-2 Navigation Mode
Figure 4.8-3 Mapping Mode
4.9. Error Clearing
When the cart encounters an error, a warning sign in the upper right corner will display the number of errors and be marked yellow. Clicking the icon will show detailed information. After the error is resolved, clicking the “Clear Error” button will make the error disappear. When there is an “Elevator Not Exited AGV Mode” condition, a “Release Elevator” button will be displayed. Clicking this button will exit the elevator from AGV mode.
Figure 4.9-1 No Error
Figure 4.9-2 Contains Errors
Figure 4.9-3 Elevator Not Exiting AGV Mode Error
Table 4.9-1 Error Codes
Error Code |
Description |
1001 |
Low Battery Warning |
1002 |
Charging Fault |
1003 |
Battery Temperature Abnormal |
2001 |
Path Planning Failed |
2002 |
Position Lost |
2003 |
Target Unreachable |
3001 |
Obstacle Detection Timeout |
3002 |
Collision Warning |
3003 |
Emergency Stop Triggered |
4001 |
Communication Failure |
4002 |
Sensor Abnormality |
4003 |
Hardware Failure |
5001 |
Point configuration file read failed |
5002 |
Point Does Not Exist |
5003 |
Elevator status unavailable |
5004 |
Elevator Mode Switching/Request Abnormality |
5005 |
Elevator action wait timeout |
5006 |
Elevator Entry and Exit Safety Conditions Fail |
5007 |
Initial Position Confirmation Failed After Layer Change |
5008 |
Task Completion Status Unconfirmed |
5009 |
Ladder Control Execution Failed |
5010 |
Elevator has not exited AGV mode |
4.10. Coarse Positioning
4.10.1. Overview
Coarse positioning function includes manual coarse positioning and automatic coarse positioning, used when the map changes, to enable the robot to automatically recognize the surrounding environment and match the correct pose through the user operating on the page -> issuing commands to the controller -> calling the algorithm.
When using the manual coarse positioning function, it is necessary to determine the correct pose under ideal conditions based on the current application map and the robot’s current pose. Then, log into the system and manually select the position and orientation on the page. After the command is issued, the robot correctly identifies the pose and adjusts the point cloud layer position.
When using the automatic coarse positioning function, it is necessary to clearly inform the user that this is an automatic match, and if not accurate, they can manually adjust the coarse positioning as needed. After the user confirms and issues the automatic coarse positioning command on the interface, the robot correctly identifies the pose and adjusts the point cloud layer position.
4.10.2. Preparation Before Use
Before performing the manual coarse positioning and automatic coarse positioning functions, please confirm the following conditions:
AMR control system can log in successfully, and the page loads normally;
The robot has been powered on normally and is in working condition (the green status light is constantly on);
AMR control system can receive map data and properly apply the selected map;
After applying the map, return to the home page - default dashboard, and check the map area on the right. At this point, the map and point cloud data have been loaded.
4.10.3. Manual Coarse Positioning Function Operation Procedure
Step1: Enter Map Editing
When the “Manual Coarse Positioning” button is clicked, a user prompt pop-up window is displayed, indicating the operation mode, habit settings, and other content. After the user confirms, the map interaction mode can be activated. At this time, the mouse entering the map area is displayed in an “pen” shaped editing state, and the map area supports click, drag, and other events.
Figure 4.10.3-1 Enter Map Editing Mode
Figure 4.10.3-2 Trigger User Prompt Box
Step2: Manual coarse positioning of directed line drawing and calculation
Allow left-clicking in the scene to obtain the current position of the chassis (starting point), while dragging to draw a line with an arrow. Release the left mouse button to get the current position (end point). Store the starting point, end point, and radian data as needed. The calculation method for the radian is the angle between the line connecting the two points and the x-axis. The specific operation process is as follows:
Click the “Manual Coarse Positioning” button, allowing you to left-click with the mouse to pick up 2D map plane coordinates in the map scene. Press the mouse to get the current position (starting point), keep the left mouse button pressed and drag the mouse to draw a directional line, release the mouse to get the current position (end point). Among these, Table 3.4.7-1 is the name of the events listened to during the drawing process, and Table 3.4.7-2 is the interaction state quantity;
The interface displays a line with a start and end point, direction, and length, and stores the position information of the start and end points;
After releasing the mouse, convert the starting point to x, y in the current map coordinate system, with units in meters. The angle between the line connecting the two points and the x-axis is used as theta, with units in radians.
Table 4.10.3-1 Listening Events
Event |
Concept |
Output Items |
pointerdown |
Press |
Starting Point Coordinates |
pointerup |
Lift |
Termination Point Coordinates |
pointercancel |
Gesture Interruption (Optional) |
/ |
Table 4.10.3-2 Error Codes
Event |
Concept |
IDLE |
Initial Editable State |
DRAGGING |
Dragging State |
SENDING |
Data Transmission Status |
LOCKED |
Edit Complete Lock State |
Step3: Command Issuance and Feedback
Front-end sends data to the backend interface, which forwards it to the AMR_Control layer, completing the initial pose setting.
The frontend passes this set of data to the Web backend through the existing interface, and the backend forwards the Control command setInitialPose.
Control First perform the map operation admission. The current mode must be manual, the safety status should be normal, there should be no active or queued tasks for navigation, the wheels must have been confirmed to be stationary, and no other map operations should be occupying. If the conditions are not met, an error code is returned and the pose is not published.
After the access is granted, Control constructs the map coordinate system pose according to x, y, theta, with position covariance set to 0.25 and orientation covariance set to 0.0685, then publishes it to /initialpose, and initiates a round of relocalization. The successful receipt code is 0, message is OK, data is null, indicating that the pose has been published.
Pose published correctly, system interface adjusted successfully.
Figure 4.10.3-3 Pose Adjustment Completion
4.10.4. Automatic Coarse Positioning Function Operation Procedure
Step1: User confirms automatic coarse positioning
When the “Automatic Coarse Positioning” button is clicked, a pop-up window is triggered to prompt the user to confirm the current operation. When “OK” is clicked, the automatic coarse positioning command is issued, and the chassis automatically repositions; when “Cancel” is clicked, the operation does not take effect.
Figure 4.10.4-1 Trigger User Confirmation Box
Step2: Command Issuance and Feedback
User confirms, and the Web backend sends autoRelocalize to Control, with params being empty. Control reuses the map operation admission for manual coarse positioning, and requires that the line registration service is available.
After passing, call /line_registration/register, the service type is line_registration_server/srv/RegisterLines, and the request is empty. The registration node calculates based on /map and /scan, and when successful, it publishes /initialpose by itself. When the error_code returned by the service is 0, the Control receipt code is 0, and the message is OK, indicating that the registration was successful and the pose has been published. The robot remains in manual and stationary mode, with subsequent actions determined by the user. The default timeout for the registration response is 30 seconds.
Control subscribes to /initialpose, incorporating this publication into the current positioning confirmation. The command receipt only indicates the registration result, and the positioning confirmation is written to the log. No new 8081 status field is added in this instance, nor is a second receipt sent. For service unavailability, registration failure, response timeout, and being stopped during the waiting period, it is proposed to return 1100424, 1100425, 1100426, 1100427, respectively.
Pose published correctly, system interface adjusted successfully.
Figure 4.10.4-2 Pose Adjustment Completion
4.11. Map Operation
4.11.1. Amplify
Note
Name: Map Zoom In Button
Explanation: Click the button, and the map will zoom in step by step. The scroll wheel zooming remains continuous.
Figure 4.11.1-1 Map Zoom In
4.11.2. Reduce
Note
Name: Map Shrink Button
Description: Click the button, and the map will decrease in a stepwise manner, while the scroll wheel zooming remains continuous.
Figure 4.11.2-1 Map Zoom Out
4.11.3. Positioning
Note
Name: AMR Cart Positioning Button
Explanation: When the button is clicked and highlighted, it becomes activated. The map center (virtual camera center) always follows the movement of the AMR cart. Once the user manually drags, the follow function is exited, the button turns gray, and becomes inactivated.
Figure 4.11.3-1 AMR Cart Positioning
4.11.4. Trajectory Recording
Note
Name: Map Trajectory Recording Button
Explanation: Click the button, and a “Delete Track” button will appear below. After the vehicle moves, the map interface will display the long line of the track it has moved along.
Note
Name: Map Trajectory Deletion Button
Description: Click the button to delete the existing map trajectory data.
Figure 4.11.4-1 Map Trajectory
4.12. Operation Control and Safety Monitoring
4.12.1. General Safety Foundation
Mode Awareness: The safety PLC always knows the current operating mode (manual/automatic).
Independent Monitoring: Safety PLC continuously monitors the actual movement status of AMR through proximity sensors.
4.12.2. Manual Mode Process (Joystick Control)
Control path: Operator -> Joystick HMI -> Main Controller -> Motor Driver -> Motor.
Safety Handshake: The main controller, while controlling the motor, sends real-time speed commands to the safety PLC.
Safety Logic:
When the joystick returns to center, the main controller sends a zero-speed command.
Safety PLC checks whether the actual speed is zero after a 0.5 second delay.
Verification failure (still in motion) -> triggers emergency stop. After the emergency stop is triggered, the vehicle, through the input from the emergency stop button and LiDAR, processes via safety PLC logic, and cuts off the power supply to the servo drive through a relay, triggering the brake on power loss.
4.12.3. Automatic Mode Process (Task Control)
The core of this mode is the legitimacy of task instructions and the predictability of status.
Task Initiation Phase - Safety Startup Permission
Command Issued: The scheduling system sends task instructions to the main controller (such as: proceed to point X).
Safety Notice: The main controller must send a clear “task start” safety signal to the safety PLC before executing a motion. This signal essentially informs the safety PLC: “The upcoming motion detected is triggered by a legitimate automatic task, please allow.
Safety PLC response: After receiving the “task start” signal, the safety PLC clears the alarm for “unjustified movement” and enters the automatic task motion monitoring state.
Task Execution Phase - “Motion Process Monitoring
Normal Control: The main controller plans the path, controls the driver, and drives the robot to move towards the target.
Continuous Monitoring: In this phase, the safety PLC, in addition to monitoring regular safety sensors (emergency stop, collision prevention, area), will also:
Verify that the motion command and mode match.
Monitor overspeed, excessive positional deviation, and other faults.
Task Completion Phase - Safety Status Confirmation
Task completion: Main controller confirms that the robot has reached the target, and the task logic is completed.
Safety Notice: The main controller must send a “task completed” safety signal to the safety PLC. This signal informs the safety PLC: “The planned automatic movement has now ended, and the robot should enter a stationary or standby state.
Safety PLC logic switching: After receiving the “task completion” signal, the safety PLC updates the expected state to “stationary”. At this time, if any non-instructed movement is detected again, strict monitoring will be restored.
4.12.4. Critical Safety Fault Logic (Automatic Mode)
Fault Scenario: The safety PLC has not received the “task start” signal.
Safety Response: In this state, the default expectation of the safety PLC is that there should be no automatic motion.
If the safety PLC detects that the AMR is in motion at this time, it will immediately be judged as “unauthorized abnormal movement” or “command loss fault”. The safety PLC will immediately trigger a protective stop and report the corresponding fault code.
4.13. General
4.13.1. Radar Settings
In the “Settings - General” module’s radar settings module, it supports the enable and disable of the radar protection function.
Figure 4.13.1-1 Pose Adjustment Completion
4.13.2. AMR Device Renaming
In the AMR device renaming module of the “Settings - General” section, it supports naming the AMR cart. After naming, the cart name can be viewed in the device information on the default dashboard interface. For example, if the cart is named “Cart 1”, the name displayed in the device information will be “Cart 1”.
Figure 4.13.2-1 AMR Equipment Renaming
Figure 4.13.2-2 Default Kanban - Device Information
4.13.3. Network Settings
In the network settings module of the “Settings - General” section, view or modify the local IP, subnet mask, and gateway of the AMR controller. The parameters are all in IPv4 dotted decimal format, with four segments of 0~255, and the subnet mask must be a legal form of consecutive 1s. At the same time, the principle of “network self-consistency” should be followed: after the operation between IP and subnet mask, the IP and gateway must fall within the same network segment. This is the only configuration entry for the user’s on-site local area network, and upon completion of the settings, a pop-up window will prompt “Please restart the AMR”.
Figure 4.13.3-1 Network Settings
4.14. Maintenance
4.14.1. Diagnostic Function Maintenance
Through the maintenance entry in the system settings, the connection status of each hardware device can be monitored in real time. When there is a cable connection error or omission, the system will display an abnormal alarm and provide specific error descriptions in the diagnostic information, facilitating quick problem location.
Figure 4.14.1-1 Diagnostic Interface
The specific operational procedures are as follows:
Step1: Click the “One-Click Diagnosis” button in the upper right corner of the interface;
Step2: Check the status feedback of each device;
Step3: Troubleshoot based on the possible error messages listed below:
Front and Rear Radar Status:
WARN: no scan >2s: The most recently received topic was more than 2 seconds ago, the radar may be briefly offline;
FAIL: no scan >20s: The most recent received topic was more than 20 seconds ago.
IMU, BMS Status:
FAIL: RS485 disconnected (zero data): After establishing the connection, it was disconnected;
FAIL: RS485 disconnected (zero data): After establishing the connection, it was disconnected.
Safety Controller:
Warn: No data >2s: The most recently received topic was more than 2 seconds ago;
FAIL: no data >20s: The most recently received topic was more than 20 seconds ago;
FAIL: Modbus comm fault (…):Connection lost after establishment.
1~3 Shared: FAIL:never received data: The device was disconnected before it was powered on.
Servo 0/1, IO Status:
FAIL: slave state is SAFEOP (expected OP);
FAIL: slave state is PREOP (expected OP):Slave Start;
FAIL: slave state is INIT (expected OP):Slave Initialization;
FAIL: cannot execute ethercat CLI (popen) : The ethercat command has not been configured with permission for password-free execution;
FAIL: slave not found on bus: After establishing the connection, it was disconnected;
FAIL: ethercat CLI error (master not running or no slaves):The device was disconnected before it was powered on.
4.14.2. Charging Pile Equipment Status
In the “Settings - Maintenance” charging pile device status, you can view the current charging pile status compatible with the trolley, including: charging pile name, status, and the most recent feedback time (unit: ms).
Figure 4.14.2-1 Charging Pile Equipment Status
Table 4.14.2-1 Charging Pile Status
Status Code |
Status |
0 |
No Feedback |
1 |
Idle |
2 |
Occupied |
3 |
Charging |
4 |
Stop Charging |
5 |
Abnormality |
4.14.3. Elevator Equipment Status
In the “Settings - Maintenance” elevator equipment status, you can view the current elevator status adapted to the trolley, including: elevator name, mode, current floor, target floor, door status, motion status, service floors, and most recent feedback time (unit: ms).
Figure 4.14.3-1 Elevator Equipment Status
Table 4.14.3-1 Mode
Status Code |
Status |
0 |
Unknown |
1 |
Manual |
2 |
Robot |
3 |
Firefighting |
4 |
Offline |
5 |
Emergency |
null |
No Feedback |
Table 4.14.3-2 Door Status
Status Code |
Status |
0 |
Turn Off |
1 |
In Operation |
2 |
Open |
null |
No Feedback |
Table 4.14.3-3 Motion State
Status Code |
Status |
0 |
Stop |
1 |
Uplink |
2 |
Downward |
3 |
Unknown |
null |
No Feedback |